APPLICATIONS
- Load limitation on EOT cranes, industrial weighing, force measurement,…
DESCRIPTION
Annular force transducers specially designed for applications requiring a load measurement through a centred.
Material: stainless steel
Protection class: IP67
Capacities:
Material: stainless steel
Protection class: IP67
Capacities:
- 5900 Force: 3 – 5 – (7.5) – 10 – (15) – 20 – 30 - 50 – 75 – 100 – 150 – (200) kN
- 5900 HOIST: 0.2 – 0.5 – (0.75) – 1 – (1.5) – 2 – 3 – 5 – 7.5 – 10 – 15 t
TECHNICAL FEATURES
0.25% (SL-FORCE & FL-HOIST on the data sheet) | |
Combined error (non-linearity-hysteresis) | <± 0.25 % F.S. |
Repeatability error | <± 0.1 % F.S. |
Creep error over 30 min. | <± 0.1 % F.S. |
Zero shift after loading | <± 0.025 % F.S. |
Reference temperature | 23 °C |
Compensated temperature range | -10…+45 °C |
Service temperature range | -30…+70 °C |
Storage temperature range | -50…+85 °C |
Temperature coefficient of the sensitivity | <± 0.05 % F.S./10°C |
Temperature coefficient of zero signal | <± 0.035 % F.S./10°C |
Zero balance | ± 0.02 mV/V |
Nominal sensitivity | 1.5 mV/V |
Sensitivity tolerance | <± 0.3 % |
Input resistance | 700 ± 2 ohm(s) |
Output resistance | 700 ± 2 ohm(s) |
Reference excitation voltage | >5000 Mohm(s) |
Permissible nominal range of excitation voltage | 10 VDC |
Safe load limit | 3..12 VDC |
Safe load limit | 150 % F.S. |
Static lateral force limit | > 300 % F.S. |
Permissible dynamic loading | 10 % F.S. |
40 % F.S. |
Technical features on the data sheet for SL-FORCE & FL-HOIST.