APPLICATIONS
- Industrial force measurement
- Weighing of hanging silos, containers or hoppers
- Weighing on conveyers
- Hybrid weighbridge (mechanical conversion).
- Official calibration
- Hanging tanks or reactors
- Packaging, counting, dosing applications
DESCRIPTION
Universal force sensor combining accuracy, robustness and easy implementation.
- Large range of capacity: from 5 kN to 50 kN.
- Stainless steel.
- Protection class: IP67.
- Compact, small size.
TECHNICAL FEATURES
Capacities | 5 – (7.5) – 10 - (15) – 20 -30 -50 – 75 – 100 kN |
0.1 % (0.3% on the data sheet) | |
Accuracy classe | 0,1 % F.S.* |
Combined error (non-linearity + hysteresis) | <± 0.1 % F.S. |
Repeatability error | <± 0.03 % F.S. |
Creep error over 30 min. | <± 0.06 % F.S. |
Zero shift after loading | <± 0.015 % F.S. |
Reference temperature | 23 °C |
Compensated temperature range | -10…+45 °C |
Service temperature range | -25…+70 °C |
Storage temperature range | -50…+85 °C |
Temperature coefficient of the sensitivity | <± 0.05 °C |
Temperature coefficient of zero signal | <± 0.035 % F.S./10°C |
Zero balance | ± 0.02 % F.S./10°C |
Sensitivity tolerance | <± 0.3 % F.S./10°C |
Input resistance | 350 ± 2 Ohm |
Output resistance | 350± 2 Ohm |
Insulation resistance (50 V) | >5000 Megaohm |
Reference excitation voltage | 10 VDC |
Permissible nominal range of excitation voltage | 3..12 VDC |
Nominal sensitivity | 2 mV/V |
Safe load limit | 120 % F.S. |
Breaking load | >300 % F.S. |
Static lateral force limit | 50 % F.S. |
Permissible dynamic loading | 60 % F.S. |
Technical features on the data sheet fortechnical features on the data sheet..