APPLICATIONS
- Industrial force measurement in small spaces.
DESCRIPTION
Sealed and compact tension and compression sensors.
Material:
Protection class: IP65
Capacities:
Material:
- 5930: stainless steel
- 5932: anodised aluminium alloy
Protection class: IP65
Capacities:
- 5930: 200 – 300 – 500 N
- 5932: 1 – (1.5) – 2 – (3) – 5 kN
TECHNICAL FEATURES
| 1 % | |
| Combined error (non-linearity-hysteresis) | <± 1 % F.S. |
| Repeatability error | <± 0.5 % F.S. |
| Creep error over 30 min. | <± 0.25 % F.S. |
| Zero shift after loading | <± 0.25 % F.S. |
| Reference temperature | 23 °C |
| Compensated temperature range | -10…+45 °C |
| Service temperature range | -25…+70 °C |
| Storage temperature range | -50…+85 °C |
| Temperature coefficient of the sensitivity | <± 0.2 % F.S./10°C |
| Temperature coefficient of zero signal | <± 0.2 % F.S./10°C |
| Zero balance | ± 0.05 mV/V |
| Nominal sensitivity | 1.5 mV/V |
| Sensitivity tolerance | <± 0.3 % |
| Input resistance | 1000 ± 100 ohm(s) |
| Output resistance | 1000 ± 100 ohm(s) |
| Insulation resistance (50 V) | >5000 Mohm(s) |
| Reference excitation voltage | 10 VDC |
| Reference excitation voltage | 5 VDC |
| Permissible nominal range of excitation voltage | 3..10 VDC |
| Safe load limit | 120 % F.S. |
| Breaking load | > 300 % F.S. |
| Permissible dynamic loading | 40 % F.S. |