APPLICATIONS
- Silos, tanks or hoppers weighing.
- Silos, tanks or hoppers weighing.
- Industrial force measurement where space is limited.
DESCRIPTION
- Material: Stainless steel
- Protection class: IP97
- Low design
- Cost-effective solution
- Sturdy design
- Easy to install
- Whole range of mounting kits available
- Cable length: 6 m
TECHNICAL FEATURES
| Capacities | (0.3) - 0.5 - (0.75) - 1 - (1.5) - 2 - 3 - 5 - 7.5 - 10 - 15 - 20** t |
| Accuracy class | 0.5 % F.S. (0.25 % F.S. & 0.1 % F.S. on the data sheet) |
| Combined error (non-linearity-hysteresis) | <± 0.25 % F.S. |
| Repeatability error | <± 0.25 % F.S. |
| Creep error over 30 min. | <± 0.2 % F.S. |
| Reference temperature | 23 °C |
| Compensated temperature range | -10…+45 °C |
| Service temperature range | -25…+70 °C |
| Storage temperature range | -50…+85 °C |
| Temperature coefficient of the sensitivity | <± 0.1 %F.S../10°C |
| Temperature coefficient of zero signal | <± 0.1 %F.S../10°C |
| Nominal sensitivity | 1.5 mV/V |
| Sensitivity tolerance | <± 0.5 % |
| Input resistance | 700 ± 2 ohm(s) |
| Input resistance | 700 ± 2 ohm(s) |
| Insulation resistance (50 V) | >5000 Mohm(s) |
| Reference excitation voltage | 10 VDC |
| Permissible nominal range of excitation voltage | 3..12 VDC |
| Safe load limit | 150 % F.S. |
| Breaking load | > 300 % F.S. |
| Permissible dynamic loading | 40 % F.S. |
| Static lateral force limit | 10 % F.S. |
Accuracy classe 0.25 % F.S. & 0.1 % F.S. technical features on the data sheet.